What people keep running into with furnace
Complaints tagged furnace, each raised by more than one person. One-off posts are not included.
31 recurring problems · 325 people · 13 forums we read
Raised more than once
Most people first.
- 5Furnace won't turn on after new AC installationThe gas valve may have been left closed or something was missed during the recent HVAC installation, preventing the furnace from starting up when the weather turns cold. Homeowners worry that waiting too long to report the issue will make the warranty company or contractor upset about the delay.
- 5How to get a stuck blower wheel off a motor shaftA blower wheel that has spun and shifted on the motor shaft can become completely locked in place, resisting standard penetrating oil and heavy hammering. Because there is often no room for a standard puller and no spare parts available, trying to force it risks destroying the wheel hub or damaging the motor.
- 5Do rusty pipes need to be replaced if they aren't leaking?Surface rust and discoloration can sit on pipes for years without ever causing an active leak. This makes it difficult to know whether you should just ignore the coloring or pay thousands of dollars to plumbing companies quoting for a full replacement.
- 4Why does my HVAC fuse blow immediately when I turn the power on?The low-voltage control fuse keeps popping instantly upon restoring power because there is an active short circuit somewhere in the system. Replacing parts like the contactor, capacitor, or transformer won't fix the issue until the underlying short is found and repaired, leaving the system completely unusable.
- 4Why is my apartment heating vent blowing painfully hot air?The furnace is overheating due to restricted airflow caused by a missing filter or collapsed intake ducting. This pushes out aggressively hot air reaching up to 250 degrees, which makes it painful to sit near the vents and raises fears about nearby objects catching fire. Because of this extreme heat, tenants are often forced to stop using the system entirely or report it to their landlord.
- 3What to do when your return air vent is too smallAn undersized return air intake causes the AC condenser to choke, creating loud noises outside and terrible system efficiency. Routing additional returns through walls and crawlspaces is difficult work that typically requires a professional.
- 3Furnace making a humming noise even when it is not runningA low-frequency hum or vibration coming from a furnace often traces back to an electrical issue or a stuck blower motor that is receiving power without spinning. While shutting off the furnace breaker stops the sound immediately, simply replacing components like the capacitor does not always resolve the underlying motor failure.
- 3What size heat pump do I need for a waterfront cottage?Choosing the right heat pump size and brand for a waterfront property requires balancing reliability with unique conditions like high wind and intermittent use. Oversizing or undersizing units, such as putting an 18k head in a 500 square foot loft, complicates quick warm-ups and leaves owners stuck trying to compare brands like Trane, Carrier, Rheem, and Goodman.
- 3Why is water blocking my Bryant HVAC exhaust pipe?Water builds up in the exhaust pipe during heating mode, physically preventing air from exiting the building. This leaves people unsure if they should open pipe caps to clean the blockage themselves or if there is regular maintenance they should be doing.
- 3Massive gaps around furnace filter and a pipe in the wayAir flows freely around massive gaps on both sides of the filter brackets, making it look like a botched upgrade missing protective foam. Attempting to replace the filter is often physically blocked by a black drainage pipe. Even after disconnecting the pipe's clamp, the leftover piece remains too long to clear the metal panel, trapping the filter inside.
- 2Why is my heater shaking violently or humming through vents on startup?Turning on a heater can trigger violent shaking that vibrates the floor, or a humming and buzzing sound that carries through distant vents for a few minutes as air begins pushing out. Because the noise may only be audible through a vent across the house rather than right next to the unit, homeowners are left guessing what is happening before paying for an inspection.