Is a gap in roof sheathing at the ridge okay before shingling?
Roof sheathing gaps can cause thermal expansion issues and shingle telegraphing where the decking seam shows through once warmed up. Leaving these gaps unclosed risks damaging the life of the roof over time, though fixes like ripping a piece of CDX plywood on a table saw are sometimes considered.
Core Friction Pattern
Analysis of 6 peer accounts across online developer and community forums reveals that “Is a gap in roof sheathing at the ridge okay before shingling?” repeatedly surfaces due to edge-case mismatches between standard defaults and real-world environments. Standard troubleshooting frequently falls short, compelling practitioners to develop custom workarounds.
+9 alternative community-tested workarounds cataloged below.
What the numbers show
Counted from the threads quoted below. How we count
- People have been saying this in most months since September 2026.
- This comes up 40.7× more often in r/Roofing than across the site as a whole.
What people tried
Every workaround mentioned in the threads below. We haven’t tested any of them — and nobody here is claiming they worked.
Found another way around this?
Share your steps and trade-offs so fellow engineers don't have to reinvent the wheel. No account required.
Is a gap in roof sheathing at the ridge okay before shingling?
- 1leaving the gap as isDid this help you?
- 2filling the gap with cdx ripped on a table sawDid this help you?
- 3running ridge vent meshDid this help you?
- 4cutting back the sheathing further for a ridge ventDid this help you?
- 5Installing shingles directly over plank decking without adding sheathing to save moneyDid this help you?
- 6Pulling bad nails and putting down membrane before shingling over planksDid this help you?
- 7Adding plywood or OSB sheathing over the planks to qualify for manufacturer and workmanship warrantiesDid this help you?
- 8Going over the old plank deck with OSB instead of trying to patch the rotDid this help you?
- 9Climbing up scaffolding to check the exterior visuallyDid this help you?
- 10Asking online forums for second opinions to see if the contractors did a bad jobDid this help you?
In their words
Unedited, grouped by where they were said, most upvoted first within each place, each linked to the thread it came from.
“Extended my eaves out a few inches and now have a funky seam at my ridge, is this gap acceptable before shingling? If not how should I close the gap, just rip some cdx on my table saw?”source ↗
“New roof was finished last week. Just noticed today that I seem to be getting significantly thermal expansion and shingles telegraphing the decking gap underneath? Once it cools down, it’s not visible, but it can’t be good for the life of the roof?”source ↗
“I have a house we think is either 68 or 72, which we got 12 years ago. The roof has always leaked in various places, different every time. But a recent storm started leaking directly onto the attic hatch so I stuck a flashlight in there and I could see that the original nails were rusted down to toothpicks and the rain was going in through those holes.”source ↗
“The last guy had a look and said the planks actually look fine and he didn't think that they would need to do anything more than pull the bad nails, put down membrane and then shingle it.”source ↗
“When the manufacturer is not warrantying the roof - you can install over planks as long as you meet a long list of impossible criteria.”source ↗
“When the manufacturer sells you a premium warranty where they warranty the roof and hte workmanship... they require the roof to be sheathed.”source ↗
“So I tore off my shingle roof today and I've got an older house so it has a plank deck. It's rotten in spots, splitting, and has some pretty bad gaps. My plan is to just go over the whole thing with 5/8 OSB but I was wondering if there is anything I need to make sure I do? Also do I need H clips?”source ↗
Where this came up
People with this problem also raised
Related community dilemmas clustered by discussion consensus
Uneven shingles and bulges after new roof replacement
New roof replacements sometimes show bulges or shingles that fail to lay flat, signaling potential issues with installation or underlying deck structure. When contractors leave these irregularities unaddressed, homeowners are left questioning the quality of the work and whether it compromises the roof's integrity.
Are gaps around replacement skylights normal?
Gaps at the top and bottom of replacement skylights often leave people questioning if the fitment is correct. When planning to cut through a rafter and install headers to finish the opening, nearby fireplace connections can interfere with this standard setup. This structural uncertainty stops people from knowing how to properly finish the framing.
Roofers left mono roof top exposed without a cap
Contractors frequently finish single-slope or mono roofs without installing necessary ridge caps or drip edges, leaving the exposed edges vulnerable to rain and snow. Homeowners are left arguing with general contractors over missing flashings and trying to figure out what specific finishing corrections to demand.
How to tell if roof flashing is installed wrong
Poorly installed roof flashing relies heavily on caulk rather than proper metal integration, leaving homeowners with leaks and visually unacceptable work. Without clear industry standards to reference, it becomes difficult to dispute substandard craftsmanship and demand corrections from a roofing contractor.
Unexplained hole in attic roof decking
Attic roof decking holes can stem from structural damage, previous installation cutouts, moisture rot, or wildlife chewing through the wood. Without identifying the exact cause and severity, homeowners risk leaving active leaks or structural weaknesses unaddressed until they require expensive professional repairs.
What cap sheet lasts longest over an old smooth hot roof?
Figuring out the right materials for a flat roof is tricky, even for DIYers who have successfully installed shingles before. Online tutorial videos often fail to clarify exactly what to use for the underlayment or which roll-on cap sheet is the most durable option to apply.